Gas Water Heater Pilot Light Will Not Stay Lit: What to Check
A pilot that lights and then goes out is losing its flame signal or fuel. The thermocouple, gas control, air and venting are the checks; a gas smell is a utility call.
A gas water heater pilot has one job: prove to the gas control that a flame is present, so the main burner can open. When the pilot lights and then dies, that proof is failing, or the flame is losing its fuel or air.
The sequence, in order
- Gas reaches the pilot. A closed valve, an empty supply or a blocked orifice stops it.
- The pilot flame is strong enough. A weak flame may not heat the thermocouple or sensor enough.
- The flame is proven. The thermocouple or thermopile generates a small signal; an electronic unit uses a flame sensor.
- The gas control holds the pilot. If the signal is weak or the control is faulty, the pilot drops out.
- The main burner lights. Air, venting and gas pressure affect this stage.
A pilot that goes out after a few seconds is usually failing at step 3. A pilot that will not light at all is failing at step 1 or 2. A unit that lights and then soots or backdrafts is a venting/air problem.
Safe checks
- Confirm the gas supply valve at the unit is open.
- Follow the manufacturer's lighting instructions exactly; do not hold the knob longer than specified.
- Check that the pilot flame is blue and steady, not yellow or lifting off.
- Look for soot, a disconnected vent or a blocked combustion-air opening.
- Do not dismantle the gas control or drill out the pilot orifice.
If the pilot lights and goes out repeatedly, stop relighting. Repeated relighting does not fix the cause and can leave unburned gas.
What a technician checks
The technician confirms the model, the gas pressure and the pilot flame, then tests the thermocouple or sensor and the gas control. The venting and combustion air are inspected. A dirty pilot assembly is cleaned; a failed thermocouple, thermopile, igniter or gas control is replaced.
The repair is the part that failed, not a sequence of guesses. If the venting is unsafe, that is addressed before the unit is returned to service.
Repair or replace
A pilot assembly, thermocouple, thermopile or gas control on a sound tank is a normal repair. A tank that is leaking, a corroded flue or a unit that keeps failing at the same gas component shifts the decision toward replacement.
A no-hot-water call is not automatically a replacement call. The tank's condition is assessed alongside the ignition fault.
When to call
Call (989) 601-2666 if the pilot will not stay lit, the flame is yellow or there is soot. If you smell gas, leave and call the gas utility first. The phone line is answered 24 hours a day.
For the service detail, see gas water heater repair or the Sage gas repair page.