A gas water heater has a fuel side and a water side, and the symptoms separate them. No hot water with a pilot that will not stay lit is a fuel or ignition problem. Hot water that runs out with a healthy flame is a tank, sediment or demand problem.
Call (989) 601-2666. If you smell gas, leave the building and call the gas utility first.
The ignition sequence
A standing-pilot unit lights a small flame and holds it with a thermocouple or thermopile. An electronic-ignition unit sparks or uses a hot-surface igniter and proves the flame with a sensor. In both cases, the gas control opens only when the flame signal is proven.
A pilot that lights and then goes out is losing that proof or its fuel. The common points are:
- A dirty or misaligned pilot orifice or burner.
- A thermocouple or thermopile that has drifted or failed.
- A gas control valve that will not hold the pilot.
- A flame sensor that is dirty or disconnected on an electronic unit.
- Combustion air or venting that is pulling the flame away.
The assessment checks the sequence rather than replacing parts in order.
Venting and combustion air
A gas unit needs enough air and a vent that drafts correctly. A blocked flue, a disconnected vent, a crowded closet or a backdraft can cause the flame to fail, and can be a safety issue beyond the pilot. Water at the flue or soot around the draft hood is a reason to stop using the unit and assess it.
A gas smell, a yellow flame, soot or a backdraft is not a "try another thermocouple" situation. Those signs need the fuel or venting addressed.
What the visit covers
The technician confirms the model and input, checks the gas supply and the pilot or ignition sequence, inspects the flue and combustion air, and tests the unit through a heating cycle. The failed part is identified before it is replaced.
If the tank is leaking, the gas repair does not solve the leak. If the tank is sound but the venting is unsafe, the venting is part of the repair. The visit separates the two.
Repair or replace
A thermocouple, igniter, flame sensor, pilot assembly or gas control on a sound tank is a repair. A leaking tank, a corroded flue, a cracked heat exchanger on a tankless unit or repeated gas-control failures point toward replacement.
A repair is not recommended merely because the unit is old, and replacement is not recommended merely because the pilot went out.
Permits and coverage
A gas repair that replaces a component is not automatically a permitted change-out. A replacement or a change in venting can be permitted work; in Tustin, plumbing and mechanical change-outs require a city permit. The address decides the path.
The service covers Tustin and the assigned places listed on the service areas page. The Riverside County places follow their own jurisdiction for permitted work.
Related decisions
- Tank water heater repair for tank and venting faults.
- Tankless water heater repair for on-demand ignition and error codes.
- Water heater replacement if the tank or venting is the real problem.