A larger custom home can hide its water heater in a far mechanical room with a long flue, and that distance matters when the burner will not stay lit. Oak Haven Estates gas calls often come down to draft and combustion air rather than a failed part.
Before touching the unit
A gas smell is the gas supplier's call. Leave, phone from outside, and do not operate a switch near the heater. Soot, a yellow flame or spillage at the draft hood means the unit stays off until it is assessed.
Fuel, then flame proof
With the gas cock confirmed open, the next question is whether the flame proves. A standing pilot depends on a thermocouple or thermopile; an electronic model depends on an igniter and flame sensor. Either can fail cleanly, and either can fail because the flame itself is weak.
A flame that lifts, flutters, or burns yellow is telling you about air or pressure, not about the sensor.
The long flue
A remote heater with a long or elbows-heavy vent is sensitive to blockage and to negative pressure inside a tight house. The vent is checked against the model's listing, including termination and rise. Combustion air is checked at the same time, because a sealed mechanical closet can starve a burner that otherwise tests fine.
If the vent cannot be brought into compliance, the heater does not go back into service.
What the visit includes
The model, fuel supply, ignition and flame proof, gas control, vent, combustion air, relief valve, and discharge are all checked.
A leaking tank or an unfixable vent moves the decision to replacement in Oak Haven Estates. A tank fault is tank repair in Oak Haven Estates.