A tankless heater in Sage reports its own fault before it quits entirely. The display code is the starting point; the manual for that exact model is the only reliable decoder.
Read the fault, not the internet
Record the brand, model and code. Codes are not shared across manufacturers; the same number can mean a different fault on another model. Use the manual for that unit, or have the technician read it.
A reset can clear a transient fault, but a fault that returns is the useful signal. Do not open a sealed combustion chamber to force the unit to run.
Flow and activation
Firing requires enough flow through the unit. A restricted inlet screen, a sticking sensor, a valve that is not fully open, or a low-flow fixture can each keep the burner off. When one tap works, the unit is probably fine and the restriction is at the other outlet.
At a private-water address, the supply pressure and any filtration are part of the flow picture. They are checked at the property.
Fuel, ignition and venting
A gas unit needs adequate pressure at its inlet, a working igniter and a flame sensor, and a vent that meets the model's clearances. A blocked vent, a bad termination or a condensate trap that will not drain can produce a lockout.
A unit that fires and then shuts down may be hitting a temperature limit, losing flame signal or seeing a vent fault. The sequence is tested.
Scale and the exchanger
Scale on the exchanger reduces heat transfer and can trigger codes. Descaling uses the unit's service valves and a manufacturer-approved solution. A heavily scaled or cracked exchanger may need replacement.
The visit
The fault history is read first, then flow, filter condition, fuel pressure, vent termination, condensate drainage, and the ignition sequence. The failed part is replaced; a unit that is simply too small is a separate installation in Sage conversation.
A storage tank is handled under tank repair in Sage.