New Water Heater Leaking From the Top: What Is Wrong?
A top leak on a new heater is usually a connection, the relief valve or condensation, not a failed tank. Here is how those sources are told apart.
Water at the top of a newly installed water heater looks alarming, but the top of the unit is where several different things meet: the cold inlet, the hot outlet, the relief valve, the flue and, on a tankless unit, the heat exchanger connections. A top leak is not automatically a failed tank.
The likely sources
A threaded connection or union. New installations can weep at the cold inlet, hot outlet or a dielectric union. The fitting may need to be re-made; over-tightening can make it worse.
The temperature-and-pressure relief valve. Water from the relief-valve discharge pipe means the valve opened. On a new unit, thermal expansion in a closed system, a failed valve or a high temperature setting can be responsible. The valve and the system pressure are checked before anything is replaced.
Condensation. A gas unit can produce condensation in the flue or on cold surfaces at start-up. A drip that appears only when the burner runs and clears later is different from a steady leak at a fitting.
A tankless connection or heat exchanger. A tankless unit has water and gas connections at the bottom or side, and a heat exchanger inside. A leak at a fitting is a connection repair; a leaking exchanger is a different decision.
A cracked tank fitting. Less common on a new unit, but a tank that is leaking at the fitting boss is a tank problem, not a union problem.
What to do
Shut the cold-water supply at the heater if the leak is active. Do not tighten gas connections or electrical fittings. If the unit was just installed, contact the installer as well as arranging an assessment; the installation is the first place to look.
If the relief valve is discharging, do not cap it or plug it. That valve is a safety device. The cause of the discharge is the problem.
How the sources are told apart
A service visit looks at the connection points, the relief-valve discharge, the flue and, where relevant, the condensate path. It checks the system pressure and the expansion control. A tankless unit gets its connections and exchanger checked.
The repair follows the source: re-making a connection, replacing a relief valve after checking the cause, addressing expansion, or replacing a failed tank or exchanger. A top leak is not a reason to replace a new tank without identifying the source.
Why a new installation can leak
A new unit is a new set of joints. The tank may be sound while a union weeps, the relief valve may be faulty, or the system may have no expansion control on a closed supply. Those are installation and component issues, not evidence that the heater was defective.
When to call
Call (989) 601-2666 if the leak is active, the relief valve keeps discharging or the source is not obvious. The phone is answered around the clock.
For the service path, see water heater leak repair and gas water heater repair if the unit is gas.